Voltage: 120 — 480

Kohler Generator Inventory

Key Facts: Kohler generators feature Fast-Response technology, PowerBoost systems, and KOHLER Command PRO engines. Available in Tier 2-4 emissions ratings for California compliance.

Browse our Kohler generator inventory below — diesel, natural gas, and bi-fuel units from 100kW to 1,500kW, including the popular 125REZGT and 1500REOZDD. For full model comparisons and buying guidance, visit our Kohler Generators brand page or read our Kohler buyer's guide.

Popular Kohler Generator Models

ModelPower RangeFuel TypeApplication
125REZGT100KWNatural Gas8,000-2,000
150REZGT125KWNatural Gas5,000-0,000
180REOZJD180KWDiesel Tier 32,000-8,000
500ROZD71500KWDiesel5,000-5,000
1000REOZDN1000KWDiesel65,000-85,000

About Kohler

Founded in 1873 by John Michael Kohler, Kohler Co. entered the power generation industry in 1920 with their first generator. What separates Kohler from competitors isn't just the Wisconsin manufacturing—it's the integrated design philosophy. While others outsource components, Kohler manufactures engines, alternators, controllers, and enclosures in-house, ensuring perfect compatibility and single-source warranty support through their global network of 800+ dealers.

Why Choose Kohler Generators?

Fast-Response Technology

Kohler's patented Fast-Response excitation delivers full-rated power in less than 10 seconds, beating industry standard 30-second startup times

PowerBoost Technology

Maintains voltage stability within 1% during block loading, critical for sensitive equipment in hospitals and data centers

Integrated Manufacturing

Unlike competitors who outsource, Kohler manufactures engines, alternators, controllers, and enclosures in-house for perfect compatibility

CARB Compliance Leader

Most extensive line of CARB-certified natural gas generators, meeting California's strictest emissions standards

2-Hour Emergency Service

Factory-certified technicians available within 2 hours anywhere in Southern California, beating competitor 4-hour response times

Frequently Asked Questions

Why do hospitals choose Kohler over Caterpillar generators?+

Kohler's integrated paralleling controls allow seamless load sharing between multiple units without external switchgear. Their PowerBoost technology maintains voltage within 1% during block loading—critical for sensitive medical equipment. Plus, Kohler's 2-hour emergency service response beats Caterpillar's 4-hour standard in Southern California.

What's the real difference between Kohler Tier 2 and Tier 3 diesel generators?+

Beyond emissions (Tier 3 produces 50% less NOx), the key differences are operational. Tier 2 units are simpler, with no aftertreatment systems—ideal for standby applications under 100 hours/year. Tier 3 adds exhaust gas recirculation (EGR) but runs cleaner for mobile applications. In California, Tier 3 is required for portable use over 50HP.

How long do Kohler generators actually last?+

With proper maintenance, Kohler diesel generators average 15,000-20,000 hours before major overhaul. Natural gas units typically reach 25,000-30,000 hours. We have customers running 1990s Kohler units with 40,000+ hours. Compare that to residential-grade units failing at 2,000 hours.

Can Kohler generators run on renewable natural gas (RNG)?+

Yes, all Kohler natural gas generators from 2018+ are RNG-compatible without modifications. The REZGT series actually performs better on RNG due to higher methane content (98% vs. 93% in pipeline gas). This makes Kohler the preferred choice for California facilities meeting carbon-neutral mandates.

What size Kohler generator do I need for my facility?+

Don't use generic calculators. Kohler's sizing is different because of their Fast-Response excitation. A Kohler 125REZGT (100KW) can handle the starting load that requires a 150KW generator from others. We provide free load analysis using Kohler's proprietary sizing software—it's saved customers an average of $8,000 by avoiding oversizing.

Why are some Kohler generators labeled "Power Module"?+

Kohler Power Modules (like the 1000REOZDN) are generator sets designed for parallel operation. They include integrated paralleling controls, allowing you to combine multiple units for redundancy. Instead of one 2000KW generator, use two 1000KW modules—if one needs service, you still have power.

What's Kohler's warranty compared to others?+

Kohler offers the industry's most comprehensive warranty: 5 years/5,000 hours on standby applications, 2 years/8,760 hours on prime power. More importantly, warranty service is performed by factory-certified technicians, not third-party contractors. Claims are processed in 48 hours, not weeks.

Do Kohler generators work with solar + battery systems?+

Kohler's APM603 controller includes built-in renewable interface protocols. The generator seamlessly integrates as tertiary backup after solar/battery depletion. Kohler's load management prevents generator cycling during partial solar production—a common problem with competitor controllers.

Get Your Kohler Generator Quote (No Spam)

**Need a Kohler Generator?** Tell us your KW needs. Get real pricing. No BS. No spam. **+1 (818) 484-8550 • Get Quote**

Get Real Kohler Pricing

Select at least 2 products