Simplex Radiator Airflow-cooled Resistive Load Bank

img_6654_1 img_6654_1 img_6655_1 img_6653_1
Get More Information

Please drop us a line below and we’ll get in touch with you shortly!

    Select the to verify

    Simplex Radiator Airflow-cooled Resistive Load Bank

    Call for Price

    Details

    Simplex Radiator Cooled Resistive Load Bank Control Unit – 400KW@1pf, 480V, 3 phase 3 wire, 60Hz, Internal Transformer for 120V 1Phase – 4) 100KW Steps – Continuous Duty Cycle – Normal Operation and Overtemp Indicator Lights – Cooling Failure Censors Lock Out Load Application, Load Circuit Protection: branch circuit fuses. One set of fuses each 50KW branch. Fuses are current limiting type, 200,000 AIC, 600V, enabling safe use on large generating or UPS system

    More Information

    Additional information

    Item Number

    A8480

    Kva

    Voltage

    Manufacturer

    Weight 5 lbs

    Product Attachment

    No attachments found for this product.

    Download Images

     

    Full Details

    When your critical power systems demand precision testing and validation, the Simplex Radiator Airflow-Cooled Resistive Load Bank delivers industrial-grade performance you can depend on. Engineered for continuous duty cycles and built to handle the most demanding load testing scenarios, this 400KW powerhouse ensures your generators, UPS systems, and power infrastructure perform flawlessly when it matters most.

    Professional-Grade Load Testing for Mission-Critical Applications

    This robust load bank control unit represents the gold standard in electrical testing equipment. Whether you're commissioning new generator installations, performing routine maintenance on backup power systems, or validating UPS capacity, this equipment provides the precise, reliable loading you need to ensure system integrity and compliance with industry standards.

    Intelligent Safety Features That Protect Your Investment

    Safety isn't just a feature—it's engineered into every aspect of this load bank system. Cooling failure sensors with automatic load application lockout prevent equipment damage before it occurs, while normal operation and overtemperature indicator lights provide instant visual confirmation of system status. You'll have complete confidence knowing your testing operations are protected by multiple layers of intelligent safety controls.

    Flexible Load Management for Precise Testing

    • Four 100KW Load Steps – Incremental control allows precise load application from 100KW to full 400KW capacity
    • Continuous Duty Cycle Rating – Designed for extended testing periods without performance degradation
    • 480V, 3-Phase, 3-Wire Configuration – Industry-standard power input for seamless integration
    • 60Hz Operation – Optimized for North American power systems
    • Unity Power Factor (1pf) – Pure resistive loading for accurate testing results

    Superior Circuit Protection for Large-Scale Systems

    The advanced protection system features current-limiting branch circuit fuses rated at 200,000 AIC, 600V—one set of fuses for each 50KW branch. This exceptional interrupting capacity enables safe operation even on large generating systems and commercial UPS installations where fault currents can be substantial. Your equipment, facility, and personnel remain protected throughout every testing scenario.

    Convenient Integrated Control Features

    The built-in transformer provides 120V single-phase power for control circuits, eliminating the need for external power sources and simplifying your installation. The radiator airflow cooling system efficiently dissipates heat during continuous operation, ensuring consistent performance throughout extended test cycles while maintaining compact footprint requirements.

    Technical Specifications at a Glance

    • Rated Capacity: 400KW at unity power factor
    • Input Power: 480V, 3-phase, 3-wire, 60Hz
    • Load Steps: Four independent 100KW stages
    • Duty Cycle: Continuous operation rated
    • Cooling Method: Radiator airflow system with failure protection
    • Control Voltage: Internal 120V 1-phase transformer
    • Protection: Current-limiting fuses, 200,000 AIC, 600V per 50KW branch

    The Simplex Advantage: Proven Reliability for Critical Testing

    When you choose Simplex engineering, you're investing in decades of load bank manufacturing expertise. This resistive load bank delivers the accuracy, safety, and reliability that power professionals demand for commissioning, maintenance, and certification testing. From data centers to hospitals, manufacturing facilities to utility substations, this equipment ensures your backup power systems will perform when called upon.

    Don't compromise on the equipment that validates your critical power infrastructure. Contact Power Generation Enterprises today to discuss your load testing requirements and discover how the Simplex Radiator Airflow-Cooled Resistive Load Bank can enhance your power system testing and maintenance programs. Our team of power generation specialists is ready to provide expert guidance on configuration, installation, and application support.